V10 velashape ultrasound cavitation vacuum multipolar RF Infrared blue light body slimming +face lifting + eye wrinkle removal beauty machine

Short Description:

I. Therapy Three Functions of the Equipment: cavitation,RF,Vacuum,infrared , 40K Strong Sound Wave Fat Burning, Dissolve fat, lymphatic drainage, firm skin and enhance skin elasticity  (1) RF vacuum blue light : Combined with bi-polar RF and Blue energy; the vacuum suction. RF and Blue and  light therapy generate heat, increasing the oxygen content of skin cells.The special vacuum  massage soothes the skin and makes the heat conduction effect better. It increases the skin tissue elasticity ...


Product Detail

Video

Product Tags

photobank

I. Therapy

Three Functions of the Equipment: cavitation,RF,Vacuum,infrared , 40K Strong Sound Wave Fat Burning, Dissolve fat, lymphatic drainage, firm skin and enhance skin elasticity

 (1) RF vacuum blue light :
Combined with bi-polar RF and Blue energy; the vacuum suction. RF and Blue and  light therapy generate heat, increasing the oxygen content of skin cells.The special vacuum  massage soothes the skin and makes the heat conduction effect better.
It increases the skin tissue elasticity and makes the skin more smooth and delicate.

(2) cavitation : 40K Strong Sound Wave Fat Burning:
With collective strong sound wave head, strong sound wave of 40000HZ may be emitted to vibrate fat cells at top speed and produce numerous vacuum air pockets inside and outside the fat cells, robustly impact fat cells to generate introverted blast and disintegrate triglyceride into glycerol and free fatty acids. Then RF waves at frequency of 1M HZ is used for exhausting the integrated glycerol and free fatty acids through hepatoenteral circulation.

(3) Multipolar Radio Frequency Lipolysis
High frequency radio frequency can rapidly improve local blood circulation, cause disintegration of fatty acids and metabolism of fat cells, so as to achieve the effect of fat dissolution and weight loss.

(4)3D Negative pressure RF liposuction head:
Being integrated with the most advanced RF technology and radio frequency, the instrument may directly reach the deep-seated fat body and have the excellence of targeted positioning RF. In the fast-active state, fat cell tissue may generate friction heat, increase local temperature and remove excess fat and toxin from the body through sweat gland, enterohepatic circulation and lymph and ultimately achieve the effect of dissolving fat.
Vacuum suction and negative pressure strong force massage may directly explode thick fat. Thus, the effects are very obvious: Enhance blood circulation, accelerate the decomposition of fat, take away wastes, enhance the effect of removing cellulite, effectively improve the state of areolar tissue, remove stubborn fat and improve the sufficient absorption condition of diet products.

(5) V10 velashape  head (2x40KHZ ultrasound cavitation Vacuum RF BIO laser)
Heating (infrared + radio frequency energies
a. Enhances blood circulation and increases oxygen dissociation from oxyhemoglobin
b. Facilitates fibroblast activity
c. Increases metabolism of fat cells
d. Improves skin texture

Cavitation + RF +BIO+Vacuum Theory
The Ultracavitation+RF beauty equipment is new equipment which uses the       most advanced technology. It combines the advantage of Ultracavitation,Vacuum liposuction and RF. The Ultracavitation uses ultrasound cavitation effect to cause the air bubbles around lipocyte membranes to break up. The broken lipocyte will then be absorbed and metabolized out of human body by lymphatic system. It has a perfect treatment result for weight losing. Also we use radio frequency to alternate the electric field in the skin from positive to negative. It will produce heat under dermis then the initial collagen denaturation. Subsequent neocollagenesis then further tightens the dermal tissue and make the skin tightened, smooth and fresh.
Combination of BIO energy and Cavitation energy, Dynamic bio-stimulation increases the metabolic effectiveness of simultaneous modulated cavitation.
The Ultracavitation uses ultrasound cavitation effect to cause the air bubbles around lipocyte membranes to break up, and then the broken lipocyte will be absorbed and metabolized out of human body by lymphatic system.
It has a effective treatment result for weight losing. burning fat cell , explode fat cell etc .
Vacuum suction and negative pressure strong force massage may directly explode thick fat. Thus, the effects are very obvious: Enhance blood circulation, accelerate the decomposition of fat, take away wastes, enhance the effect of removing cellulite, effectively improve the state of areolar tissue, remove stubborn fat and improve the sufficient absorption condition of diet products.

II. Process for Fat Dissolution
For body slimming
Step 1: Use 40K fat-dissolving head to blast the fat in the fat parts;
Step 2: Use Negative pressure RF liposuction head to metabolize the fat. The eventually integrated glycerol and free fatty acids are discharged out of the body through hepatoenteral circulation.
Step 3: Use multipolar RF in the fat parts

1

For face lifting,eye wrinkle removal
Use RF vacuum blue light for the body part in the fat parts 

2

III. Instruction for Instrument Accessories

3

Vacuum RF blue light pen

4

40K Fat-dissolving Head

5

Multi-polar RF Fat Burning Head

6

3D Negative pressure RF liposuction head
IV. NOTES:
1. Spread essence on the treated positions for evenly
2. In use, start with low-energy. We suggest to try for the proper energy level on the back of clients' hands before using on body of them
3. Do not use gel as the medium
4. In operation, start pulling only after negative pressure head is attached to skin.
5. Turn off the instrument probe when it is not in use.

Notes for Use
1. Those suffering from severe diseases such as heart disease, gastric ulcer, serious stomach trouble, duodenal ulcers, high blood pressure, diabetes, etc can not use this instrument.
2. Pregnant women, lactating women, women who have abdominal surgery not more than three months ago, and menstruating women can not use this instrument.
3. Those that have used this instrument shall mainly eat light food and shall avoid eating high protein, high fat and high calorie food.
4. Those that have sheet metal etc implanted in their bodies (such as cardiac pacemaker) can not use this instrument.
5. Those that are extremely weak can not use this instrument.

V. Working Parameters

Input voltage: AC220V, 50HZ/AC110V, 60HZ
Power consumption: 500W
V10 velashape hand
Vacuum pressure: 0-100(KPA)
Cavitation frequency: 40KHZ
RF frequency: 5MHZ
BIO frequency: 200HZ/500HZ
BIO pulse width 100us/300 us
Infrared wavelength: 650nm
3D vacuum RF infrared handle:Output Level: 20-95 (KPA)
Vacuum pressure: 650nm
Infrared light wavelength: 5000MCD
Infrared intensity: 20W
R.F Energy: 1MHZ
R.F Frequency:
Multipolar RF handle: 2w/cm2
Output power: 1MHZ
RF frequency: 8
Number of Output Electrodes: Continuous
Output Mode: 10
Output Level:
40KHZ cavitation handle: 40KHZ
Cavitation frequency: 5W/cm2
Output Power: Pulse
Output Mode: 8
Output Level:
Eye vacuum RF head 20-95(KPA)
Vacuum pressure: 1MHZ
RF frequency: 490nm
Blue light wavelength:  
     

VI. Servicing and Maintenance
1. The mainframe of this instrument is guaranteed (with proof of purchase) for half a year calculated from the purchase date. We may also repair or update other parts that are not within the scope of warranty or whose warranty period has expired but will charge corresponding fees incurred thereby. Please contact the dealer if any part, accessory or consumable needs to be supplemented or purchased.
2. We will not provide free reparation service within warranty period for the following failures caused by the user.
A. Failures caused by the user’s disassembly or modification of this product without permission;
B. Failures after being broken or falling off caused by the user’s careless use;
C. Failures caused for lack of reasonable maintenance;
D. Failures caused by failure to follow the correct guidance of the instruction.

3. Specifications of our product are subject to change without notice. If there is any question, please contact the company.
Attachment: List of Accessories

Name Unit Quantity
40K strong ultrasonic head Piece 1
Multipolar radio frequency head Piece 1
Vacuum RF infrared pen Piece 1
3D Negative pressure RF liposuction head Piece 1
Power line Piece 1
Instruction book Copy 1
V10 velashape handle Copy 1

LECH


  • Previous:
  • Next:

  • Write your message here and send it to us